RIGOL  Chapter 17 Function/Arbitrary Waveform Generator (MSO7000 Option) 
17-16  MSO7000/DS7000 User Guide 
rate of data transmission. 
 
1.  Set the Modulation Polarity 
Press Polarity continuously to select "Positive" or "Negative" of the modulating 
waveform to control the frequency output. 
 
2.  Set the Modulation Rate 
Press FSK Rate, then rotate the multifunction knob    or use the pop-up 
numeric keypad to set the frequency of the modulation signal. The available 
range is from 1 Hz to 50 kHz. 
 
3.  Set the Hopping Frequency 
Hopping frequency indicates the frequency of the modulating waveform. The 
range of the hopping frequency is from 100 mHz to the maximum frequency of 
the carrier waveform. By default, it is 10 kHz. Press Hop Freq, then rotate the 
multifunction knob    or use the pop-up numeric keypad to set the hopping 
frequency.   
 
 
Sweep 
 
The built-in Function/Arbitrary Waveform Generator of MSO7000 series oscilloscope 
supports the sweep function. In the sweep mode, the Function/Arbitrary Waveform 
Generator outputs from the start frequency to the end frequency at a specified 
sweep time. MSO7000 series supports 3 sweep modes: Linear, Log, and Step. You 
are allowed to set the parameters such as Start Keep, End Keep, and Return Time. 
Internal, External, and Manual trigger sources are supported. The sweep output is 
available for Sine, Square, Ramp, and Arb (DC excluded) waveforms. 
 
Press Settings → Type, and rotate the multifunction knob    to select "Sweep", 
and then press down the knob to select it. You can also press Type continuously or 
enable the touch screen to select it. 
 
1.  Set the Sweep Type 
Press Sweep Type, and rotate the multifunction knob    to select the desired 
sweep type, and then press down the knob to select it. You can also press 
Sweep Type continuously or enable the touch screen to select it. The available 
sweep types include Linear, Log, and Step. 
⚫  Linear: the frequency of the signal changes linearly. 
⚫  Log: the frequency of the signal changes in log form. 
⚫  Step: the frequency of the signal changes with ladder-like step. 
 
2.  Sweep Settings 
Press Settings to enter the sweep setting menu.