RIGOL  Chapter 13 Pass/Fail Test 
13-4  MSO7000/DS7000 User Guide 
them to the current pass/fail test function. 
 
 
To Set the Output Form of the Test Results 
 
Press Option to enter the "Option" menu. You can set what the oscilloscope will 
execute when test results are detected according to your needs. 
⚫  Set the output event and Aux output 
➢  Press Output Event, and rotate the multifunction knob    to select "Fail" 
or "Pass". Press down the knob to select it. You can also press Output 
Event continuously to enable the touch screen to select it. 
➢  Press Aux Output continuously to enable or disable the Aux output. If 
enabled, press Utility → System, and then the AUX Out is automatically 
set to "PassFail". When a successful or failed event is detected, a pulse will 
be output from the rear-panel [TRIG OUT] connector. If the Aux output is 
disabled, press Utility → System, and then the AUX Out is automatically 
set to "TrigOut". The output of the rear-panel [TRIG OUT] connector is 
irrelevant with the pass/fail test. 
 
⚫  Set the output polarity and output pulse width 
Press Polarity continuously to select "Positive" or "Negative". Then press Pulse, 
rotate the multifunction knob    or use the pop-up numeric keypad to set the 
pulse width. Its range is from 100 ns to 10 ms. By default, it is 1 μs. 
 
⚫  Set the error action 
Press Err Action, and rotate the multifunction knob    to set the operation 
that the oscilloscope will execute once a failed test is detected. Press down the 
knob to select it. You can also press Err Action continuously and press down 
the multifunction knob    to select it. Also, you can enable the touch screen to 
select it. 
➢  Stop: indicates stopping test when a pass/fail test event is found. 
➢  Beeper: indicates that the beeper sounds an alarm when a pass/fail test 
event is found (irrelevant with the on/off status of the beeper). 
➢  Screenshot: performs the screenshot operation when a pass/fail test 
event is found. If an external storage device is detected, the screenshot will 
be saved to the external storage device directly. Otherwise, it will be saved 
to the local disk. 
Note: If "Screenshot" is selected under Err Action, "Stop" action will be 
executed forcibly. The test will be stopped automatically. After the 
Screenshot operation is completed, the test will continue.