RIGOL Chapter 6 Specifications
6-10 DSG800 User's Guide
IEC 61000-4-11:2004/EN
61000-4-11
Voltage dip:
0% UT during half cycle
0% UT during 1 cycle
70% UT during 25 cycles
Short interruption:
0% UT during 250 cycles
Safety regulation
Conform to:
IEC 61010-1:2010 (Third Edition)/EN 61010-1:2010,
UL 61010-1:2012 R4.16 and CAN/CSA-C22.2 NO.
61010-1-12+ GI1+ GI2
Environmental
Temperature
Operating temperature range
0
to 50
Storage temperature range
-20
to 70
Humidity
0
to 30
95% RH
30
to 40
75% RH
40
to 50
45% RH
Altitude
Operating height
Below 3000 m
Dimensions
W × H × D
261.5 mm × 112 mm × 318.4 mm
(10.30 inch × 4.41 inch × 12.54 inch)
Weight
4.2 kg (9.3 lb)
Calibration Interval
Recommended
calibration interval
1 year