RIGOL  Chapter 2 Front Panel Operations 
2-16   DSG800 User Guide 
External Coupling 
 
Press EXT Coup to select "AC" or "DC" coupling and the default is "AC". 
  When "AC" is selected: the DC components of the external signal input from the 
[EXT MOD IN] connector at the rear panel of the instrument will be blocked 
and the AC components can pass through the connector.The external 
modulation input port is similar to a high-pass filter which low cutoff frequency 
is less than 5 Hz.   
  When "DC" is selected: all the AC components and DC components of the 
external input signal can pass through the connector.   
 
Note: When "Int" modulation source is selected, this menu is grayed out and 
disabled. 
 
 
Input Impedance 
 
Press Impedance to select "50ohm", "600ohm" or "100kohm ". You can set the 
impedance of the [EXT MOD IN] input channel.   
 
Note: When "Int" modulation source is selected, this menu is grayed out and 
disabled. 
 
 
 