Technology
Your new pellet stove is technologically advanced as a result of years of tests in the laboratory and in practice.
The practical advantages of your pellet stove are convincing:
Operating Comfort – Operational Reliability
The electronic monitoring device together with a combustion temperature monitoring device controls and
regulates the interplay of the flue gas fan, conveyor auger and temperature. This monitoring system guarantees
an optimum combustion and operating mode. Your operating outlay is reduced to the most necessary - this
prevents operating faults whilst working in an optimum fashion at the same time.
The flame and drive motor noises permissible for the living space are therefore audible during operation.
Highest Efficiency – Lowest Emissions
A very large heat exchanger surface together with optimum combustion air control leads to very good fuel
usage.
Finely metered pellet feed in an optimised burner pot made from high quality grey cast iron effects almost
perfect combustion with very good exhaust gas values - and this is guaranteed in every operating phase.
Automatic Safety Function
Power Failure (during heating operation)
After a power failure the operating functions that were set before the power failure are continued.
After a brief power failure, the operating functions set prior to the failure are continued. If the power failure
lasts longer, the stove goes to start phase (display START) as long as sufficient temperature or embers are
present. If the power failure lasts too long, the stove goes to STOP phase (display STOP – lasts approx. 10
minutes). Re-start is then performed automatically (display IGNIT).
Power Failure (during the start phase)
The start procedure is continued after a brief power failure. If the power failure lasts longer and there are
no embers available, then the stove goes to STOP phase. In the STOP phase (display STOP – lasts approx. 10
minutes) only the blower runs to burn off any pellet residues. Re-start is then performed automatically (display
IGNIT).
Overheating
A temperature safety switch (STB) switches the stove off automatically if it overheats. After the stove has
cooled down the STB must be reset manually. The pellet stove can now be operated manually (or by means of
a timer program) and it then goes into the regulating program again.
CAUTION: If overheating has occurred then maintenance or cleaning work must be carried out.
Low Temperature Switch Off
If the stove cools down below a minimum temperature, then the stove will switch off. This switch off can also
occur if pre-heating is too late.
Electric Excess-Current Shut Off
The device is protected against excess current by a main fuse (on the rear of the device), (data as per “Technical
Specification”).