Easy Off – Inactive State
Key Display Description
EASY
OFF
Standard display for stove
switched off in simple heating mode.
The output can also be regulated
between 30% and 100% with the
stove switched off
(EASY 30 – EASY 100).
EASY
45
Pressing increases
output by 5%
EASY
35
Pressing decreases
output by 5%
Start – Scavenge – Tip – Ignition
The pellet stove is started in the scavenging phase by pressing
the button. The scavenging phase lasts approx. 50
seconds and is used to eliminate any adverse draft conditions in
a cold flue. The grate tips automatically during the scavenging
process and any ash leftover from the previous combustion
phase falls into the ash tray.
Depending on the fill level of the screw conveyor the ignition
process can take approx. 5 to 30 minutes until the first flame is
visible.
If the first ignition attempt is unsuccessful, further ignition
attempts will be initiated automatically. This may occur if the
screw conveyor is not completely full during the ignition process
(e.g. first start after refilling empty container).
Please observe:
In the event of false start, completely empty the combustion
chamber and dispose of unburned pellets and ash. Never replace
unburned pellets from the fire pot in the supply container.
FIRE HAZARD DUE TO RESIDUAL EMBERS.
Key Display Description
IGNITE
START
EASY 35
Pressing starts the unit.
This is shown by IGNITE in
the display; this is replaced
by START after a brief time.
EASY xx appears in the
display after the start phase
(xx stands for a value
between 30% and 100%,
depending on output)