© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2011
Instructions Part Number IN1227 Ed 1
20
Main Menu Setup – Additional Functions
F R O S T
O F F
G S M
S E T
E X T
O F F
S E T U P
The frost protection is activated or deactivated by
using the + or – key. The frost protection function
is only active in connection with a room thermostat.
C - F A N
O F F
R E S E T
- 1 0 -
L O C K
O F F
R O O M
S E T
The external request is activated or deactivated by
using the + or – key. The external request function
is only active in connection with a room thermostat.
O K
2 2 ° C
The deviation in the
actual temperature
of the room sensor is
changed using the +
or – key. (adjustment
range is +/- 4 °C).
The C-Fan function is switched on or off
by using the + or – key.
The lock function is switched on or off
by using the + or – key.
All the parameters set are reset to factory
values by using the I/O key.
G S M
O F F
S M S
O F F
0 0 0 0
C O D E
0 0 0 0
The GSM
function is
activated or
deactivated
by using the
„+“ or „-„ key.
The SMS
function is
activated or
deactivated
by using the
„+“ or „-„ key.
Shows the
active code
The code
for the GSM
function can
be setted
with the „+“
and „-„ key.
With the I/O
key it can be
confirmed.
GSM - Option