Main Menu Info – Additional Functions
Key Display Description
INFO
Access to information menu, various system statuses, temperatures and operating
information can be called up here.
IN INFORMATION INPUTS
FLAME
319
Display of current flame temperature.
ROOM
22
Display of current room temperature.
EXT
ON
Display of status of external release. (ON or OFF)
DOOR
ON
Display of the status of door contact. (ON or OFF)
STB
ON
Display of the status of safety temperature limiter. (ON or OFF)
GRID
ON
Status display for the tilting grate contact (ON or OFF)
IN INFORMATION INPUTS
OUT INFORMATION OUTPUTS
AUGER
OFF
Display of operating status of screw motor. (ON or OFF)
AUGER
00
Display of actual push-in rate.
FAN
ON
Display of operating status of flue gas blower. (ON or OFF)
FAN
00
Display of speed of flue gas blower.
C-FAN
ON
Display of the operating status of the convection fan. (ON or OFF)
C-FAN
00
Display of the speed of the convection fan.
IGNIT
OFF
Display of operating status of ignition element. (ON or OFF)
GRID
OFF
Display of the operating status of the tilting grate motor. (ON or OFF)
OUT INFORMATION OUTPUTS
PAR INFORMATION PARAMETER
RUN – T
63
Display of previous total operating hours.
RUNKG
245
Display of total pellet amount supplied up to present.
SERKG
245
Display of conveyed pellet amount since the last cleaning and maintenance.
(chapter 10 cleaning and maintenance)
TPO
0124
Display of current software version loaded on control board. (marquee)
U-VER
13
Display of current software version loaded on control unit.
TEL S
12
Coding software
TEL H
1024
Coding hardware
PAR Repeated pressing of returns you to the main menu level.