Cleaning the Combustion Chamber Door Glass
The viewing window becomes coated with the very fine ash from the wood pellets, light or dark depending on
the pellet quality (especially with low output). The glass can be cleaned best with a moist cloth. Stubborn dirt
can be removed with a special cleaner available from your stove dealer.
Cleaning the Flues
The flue pipes should be cleaned at least twice a year or after approx. 700 kg pellets. The flue ducts are located
at the sides next to the combustion chamber.
Open the convection cover (part 56, page 6-7).
Please watch your fingers when doing this.
When doing this make sure that the cover securing
mechanism (part 56, page 6-7) locks into the designated
retaining bracket (see picture).
Undo the wing nut and remove the bracket that secures
the cover of the heat exchanger (see picture).
You can now lift off the heat exchanger cover and set it
to one side (see picture).