27
OPERATION PARAMETER RECOMMENDATION
1 Generally, welding current is adequate to welding electrodes according with as following
electrode
specification
φ2.5 φ3.2 φ4.0 φ5.0
welding current 50-90A 90-130A 140-210A 190-270A
2 MIG welding parameter variables
The values listed in the following table are the general parameters under standard condition.
Material
thickness
mm
Wire
diameter
(mm)
Interval
(mm)
Current
A
Voltage
V
Welding
speed
(cm/min)
Wire
extension
(mm)
Gas flow rate
(L/min)
I Square butt welding
Low welding speed
0.8 0.8,0.9 0
6070 1616.5 5060
10 10
1.0 0.8,0.9 0
7585 1717.5 5060
10
1015
1.2 0.8,0.9 0
8090 1616.5 5060
10
1015
1.6 0.8,0.9 0
95105 1718 4550
10
1015
2.0 1.0,1.2
00.5 110120 1819 4550
10
1015
2.3 1.0,1.2
0.51.0 120130 1919.5 4550
10
1015
3.2 1.0,1.2
1.01.2 140150 2021 4550 1015 1015
4.5 1.0,1.2
1.01.5 160180 2223 4550
15 15
1.2
1.2
1.6 220260 2426 4550
15
1520
1.2
1.21.6 220260 2426 4550
15
1520
1.2 1.21.6 300340 3234 4550 15 1520
1.2 1.21.6 300340 3234 4550 15 1520
High welding speed
0.8 0.8,0.9 0 100 17 130 10 15
1.0 0.8,0.9 0 110
175
130 10 15
1.2 0.8,0.9 0 120
185
130 10 15
1.6 1.0,1.2 0 180
195
130 10 15
2.0 1.0,1.2 0 200 21 100 15 15
2.3 1.0,1.2 0 220 23 120 15 20
3.2 1.2 0 260 26 120 15 20