INSTALLATION
CHECKING ROOM SIZE
The heaters MUST NOT be installed in a room smaller than specified, these are:
The Avenger 25 minimum room size 62.5 m³.
The Blaze 21 minimum room size 52.5 m³.
The Dynamo 15 minimum room size 37.5 m³.
The Enduro 13 minimum room size 32.5 m³.
To determine if the intended room meets the minimum size requirements simply multiply the Height x
Width x Depth. For example if the room dimensions are Length 5.3 metres, Width 5.0 metres and
Height 2.4 metres then the volume would be 63.6 m³ and suitable for use wit
h an Avenger 25.
DO NOT use this appliance to heat a bedroom, bathroom, toilet, combined living/sleeping area or
sauna.
GAS CONNECTION
The bayonet plug on the factory fitted flexible hose simply plugs into your bayonet fitting.
If you require more information regarding your local ventilation requirements contact
Rinnai (see back page for contact details) or your local gas regulatory authority.