Operation without the remote
Ignition
This appliance has a sealed combustion chamber that requires purging before gas can flow
and the unit can start. This means the combustion fan will start several seconds before the fire
ignites.
Normal ignition sequence:
1. When the On/Off button is pressed on the control panel, the LED will glow
blue and the combustion fan will start.
2. The ignition sparker will operate, and as soon as a spark is sensed gas will flow
to the main burner.
3. When the main burner establishes a flame, the heater will automatically
modulate between the burner settings to achieve and maintain the default set
temperature of 22 °C.
If the heater is turned off using the On/Off button on the heater control panel,
when it is turned back on, it will lose any timer and clock settings until the remote
is used to re-transmit the information. The remote stores the clock, timer, and
temperature settings of the heater.
Do not unplug power supply
Do not unplug the main power supply to turn the unit off as the convection fan is required to
operate for several minutes after the unit is turned off to assist in cooling the unit down.