Water Flow Chart
0
5
10
15
20
25
0 100 200 300 400 500
Water flow rate (l/min)
Water pressure (kPa)
REU-A1420FFU / REU-A1720FFU
REU-A1111FFU
REU-A1111W
Tin=5°C
REU-A1111FFU
REU-A1111W
Tin=25°C
REU-A1420W / REU-A1720W
Gas Pressures
11i - REU-A1111FFU-E(UK)
Gas Type G20 / Nat Gas G230 / Air Propane G30 / Butane G31 / Propane
Low Fire Setting
1.83 mbar 2.15 mbar 2.43 mbar 2.43 mbar
High Fire Setting
4.97 mbar 6.22 mbar 6.65 mbar 7.53 mbar
17i - REU-A1720FFU-E(UK)
Low Fire Setting
1.92 mbar 2.15 mbar 2.68 mbar 2.68 mbar
High Fire Setting
10.85 mbar 13.55 mbar 13.24 mbar 15.95 mbar
Enfocus Software - Customer Support
17E REU-A1720W-E(UK)
Low Fire Setting
1.58 mbar 1.89 mbar 2.29 mbar 2.29 mbar
High Fire Setting
9.0 mbar 11.57 mbar 11.6 mbar 15.1 mbar