Technical Data
Model 11i / REU-A1111FFU-E(UK) Unit
Installation Indoor / Outdoor: in partially protected area
G20 Nat Gas min gas pressure
1.83
mbar
G20 Nat Gas max gas pressure
4.97
mbar
G230 Air/Propane min gas pressure
2.15
mbar
G230 Air/Propane max gas pressure
6.22
mbar
G30 Butane min gas pressure
2.43
mbar
G30 Butane max gas pressure
6.65
mbar
G31 Propane min gas pressure
2.43
mbar
G31 Propane max gas pressure
7.53
mbar
Flue system
-
Temperature range with water controller 37-46, 48, 50, 55, 60, 65 °C
Temperature range with push buttons 40, 42, 50, 55, 60, 65 °C
Ignition Direct electronic ignition -
Gas consumption & capacities min operation
G20 Nat Gas: Input Qm: Hi/Hs | Output Pm 4.10/4.53 | 3.56 kW
0.43 m
3
/h
G230 Air/Propane Input Qm: Hi/Hs | Output Pm 4.10/4.53 | 3.56 kW
0.35 m
3
/h
G30 Input Qm: Hi/Hs | Output Pm 4.10/4.53 | 3.56 kW
0.33 kg/h
G31 Input Qm: Hi/Hs | Output Pm 4.10/4.53 | 3.56 kW
0.33 kg/h
Gas consumption & capacities nominal operation
G20 Nat Gas: Input Qn: Hi/Hs | Output Pn 21.30/23.70 | 18.90 kW
2.25 m
3
/h
G230 Air/Propane: Input Qn: Hi/Hs | Output Pn 21.80/23.70 | 18.90 kW
1.79 m
3
/h
G30 Input Qn: Hi/Hs | Output Pn 25.10/27.20 | 21.80 kW
1.99 kg/h
G31 Input Qn: Hi/Hs | Output Pn 21.80/23.70 | 18.90 kW
1.69 kg/h
Country of destination Refer to data-plate -
Gas category and pressure
II2H3P, II2H3B/P, II2HM3B/P
G20-20mbar, G230-20mbar,
G31-37mbar, G30-30mbar
-
Type C13, C33, C53, C63, C93, C(10)3 -
11 l/min
ON=2 / OFF=
1
l/min
Min operating water pressure (Pmin) 0.10 bar
1.00/1.40 - 8.30 bar
Power supply 230V/50Hz -
Electric consumption (remote/standby/anti-frost)
36/1.5/84
W
Noise level 56 dB (A)
Ignition safety time TSAmax 4.2 sec.
Weight 14.0 kg
IP protection IPx4D -
Anti-freeze temperature protection -15
2
°C
NOx 50 mg/kWh
1
2
when protected from direct wind exposure.
Enfocus Software - Customer Support
39/1.5/84
G20
G30