EasyManuals Logo

Rinnai RL94e REU-VC2837WD-US User Manual

Rinnai RL94e REU-VC2837WD-US
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
VCSeriesManual 11
FreezeProtecƟon
Makesurethatincaseoffreezingweatherthatthe
waterheateranditswaterlinesareprotecte dto
preventfreezing.Damageduetofreezingisnot
coveredbythewarranty.
LossoffreezeprotecƟonmayresultinwaterdamage
fromaburstheatexchangerorwaterlines.
Withelectrical
powersupplied,thewaterheaterwill
notfreezewhentheoutsideairtemperatureisascold
as–22°F(Ͳ30°C)forindoormodelsorisascoldas–4°F
(Ͳ20°C)foroutdoormodels,whenprotectedfrom
directwindexposure.Becauseofthe“windͲchill”
eīect,anywindorcirculaƟonoftheairontheunit
willreduceitsabilitytofreezeprotect.
Theunitmaybedrainedmanually.However,itis
highlyrecommendedthat:
x draindownsolenoidvalvesareinstalledthatwill
automaƟcallydraintheunitifpowerislost.
Theseareavailableinakit,104000059.(The
condensatetrapdrainplugandwaterdrainplug
arenotaīectedbytheautodraindownsolenoid
valvesandwillhavetobemanuallyopened.)
x asurgeprotectorwithterminalsisinstalledwhich
allowsthesolenoidvalvestooperateiftheunitis
disabledduetoadiagnosƟccode.Thisis
availableas104000057.
InaddiƟon,thesolenoidvalvesshouldbeconnected
electricallytoasurgeprotectorwithterminals.This
allowsthesolenoidvalves
tooperateifthewater
heaterisdisabledduetoadiagnosƟccode.
ThefreezeprotecƟonfeatureswillnotpreventthe
externalpipingfromfreezing.Itisrecommended that
hotandcoldwaterpipesareinsulated.Pipecover
enclosuresmaybepackedwithinsula Ɵonforadded
freeze
protecƟon.
Intheeventofapowerfailureattemperaturesbelow
freezingthewaterheatershouldbedrainedofall
watertopreventfreezingdamage.InaddiƟon,drain
thecondensatetrapanddrainline.
Maximumventlength
(indoormodelsonly)
1. Determinethenumberof90degreeelbowsin
theventsystem.(Two45degreeelbowscountas
one90degreeelbow.)
2. Refertothetabletondthemaximumvent
lengthbasedonthenumberofelbows.
3. AdjustswitchNo.1intheSW1DIPswitch(tan
switches)ifrequiredbytheapplicablenote.
MIfthelengthisgreaterthan21Ō(6.4m)then
moveswitchNo.1(SW1)toOFF.
NIfthelengthisgreaterthan15Ō(4.6m)then
moveswitchNo.1(SW1)toOFF.
OIfthelengthisgreaterthan9Ō(2.7m)thenmove
switchNo.1(SW1)
toOFF.
PMoveswitchNo.1(SW1)toOFF.
Example: Ifyouhaveoneelbowthenyourmaximum
ventlengthis35feet(10.7m).Ifyour
actuallengthisgreaterthan15Ō(4.6m)
thenmoveswitchno.1(SW1)toOFF.
Numberof
90°Elbows
Maximumventlength
0 41Ō(12.5m)M
1 35Ō(10.7m)N
2 29Ō(8.8m)O
3 23Ō(7.0m)P
4 17Ō(5.2m)P
5 11Ō(3.4m)P
6 5Ō(1.5m)P
Ifyouhavealongerventlength(seeabove),switch
No.1isrequiredtobeintheOFFposiƟon.This
ensuresthewaterheaterwillrunproperly.Blocked
uediagnosƟccodesandshutdownsmayresultif
switchNo.1isnotinthecorrectposiƟon.
NOTICE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai RL94e REU-VC2837WD-US and is the answer not in the manual?

Rinnai RL94e REU-VC2837WD-US Specifications

General IconGeneral
TypeTankless
InstallationIndoor
Energy SourceNatural Gas or Propane
Flow Rate9.4 GPM
Energy Factor0.82
Gas TypeNatural Gas or Propane
Minimum Flow Rate0.4 GPM
Voltage120V
Ignition TypeElectronic
Maximum BTU199, 000 BTU
Temperature Range98°F to 140°F
Minimum BTU Input15, 000 BTU/hr
Warranty12 years heat exchanger, 5 years parts, 1 year labor