EasyManuals Logo

Rinnai RL94e REU-VC2837WD-US User Manual

Rinnai RL94e REU-VC2837WD-US
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
34 VCSeriesManual
HowtoSettheTemperature
Whileanyhotwaterisbeingprovided,
thetemperatureseƫngcanonlybe
adjustedbetween98°Fand110°F.
NO TICE
Checklocalcodesforthemaximumwa ter
temperatureseƫngallowedwhenused
innursinghomes,schools,daycare
centers,andallotherpublicapplicaƟons.
NO TICE
Ifanewlyinstalledunitwithacontroller
hasnotbeenpoweredforatleast6hours
thenthetemperaturewillreturntothe
defaultseƫngof104°F(40°C)ifpoweris
interrupted.
NO TICE
TheremaybeavariaƟonbetweenthe
temperaturedisplayedonthe
temperaturecontrollerandthe
temperatureatthetapduetoweather
condiƟonsorthelengthofpipetothe
waterheater.
NO TICE
1. Ifthewaterheaterisoī,press
thePowerbuƩontoturnon.
2. IfthePrioritylightisoī,then
pressthe“PrioritybuƩon”onthe
temperaturecontroller.The
greenPrioritylightwillglow
indicaƟngthatthiscontrolleris
controllingthetemperatureand
that
thewaterheaterisreadyto
supplyhotwater.(Thepriority
canonlybechangedwhilenohot
waterisrunning.)
3. PresstheupordownbuƩonsto
obtainthedesiredtemperature
seƫng.
Allhotwatersourcesareableto
providewateratthistemperature
seƫng
unƟlitischangedagainat
thisoranothertemperature
controller.
DANGER
Hotwatercanbedangerous,especiallyforinfantsorchildren,theelderly,
orinrm.ThereishotwaterscaldpotenƟalifthethermostatissettoohigh.
Watertemperaturesover125°F(52°C)cancausesevereburnsorscalding
resulƟngindeath.
Hotwatercancause
rstdegreeburnswithexposureforasliƩleas:
3secondsat140°F(60°C)
20secondsat130°F(54°C)
8minutesat120°F(49°C)
Testthetemperatureofthewaterbeforeplacingachildinthebathor
shower.
Donotleave
achildoraninrmpersoninthebathunsupervised.
Thiswaterheaterrequiresaminimumowratetooperate.ThisratecanbefoundonthespecicaƟonpagein
thismanual.Insomecaseswhenyouarenotgeƫnghotwaterorifthewateralternatesbetweenhotandcold,
itisduetothewater
owbeingbeloworclosetotheminimumowrate.Increasingtheowrateshould
resolvetheseproblemsinthesecases.
Ifyouareexperiencingissueswithhighertemperatureseƫngs,thenreducethetemperatureseƫng.SelecƟnga
temperatureclosertothatwhichisactuallyusedat
thefaucetwillincreasetheamountofhotwaterbeing
deliveredtothefaucet,duetolesscoldwatermixingatthexture.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai RL94e REU-VC2837WD-US and is the answer not in the manual?

Rinnai RL94e REU-VC2837WD-US Specifications

General IconGeneral
TypeTankless
InstallationIndoor
Energy SourceNatural Gas or Propane
Flow Rate9.4 GPM
Energy Factor0.82
Gas TypeNatural Gas or Propane
Minimum Flow Rate0.4 GPM
Voltage120V
Ignition TypeElectronic
Maximum BTU199, 000 BTU
Temperature Range98°F to 140°F
Minimum BTU Input15, 000 BTU/hr
Warranty12 years heat exchanger, 5 years parts, 1 year labor