VCSeriesManual 35
TemperaturesAvailablewithaController
ThewaterheatercandeliverwateratonlyonetemperatureseƫngataƟme.Theavailabletemperaturesare
providedbelow.Atemperaturelowerthan98°F(37°C)canbeobtainedatthetapbymixingwithcoldwater.
Tochangethetemperat urescalefromCelsiustoFahrenheitorvice
versa,pressandholdthe“On/Oī”buƩon
for5secondswhilethewaterheaterisOFF.
ThesetemperaturesaresuggesƟonsonly:
* Temperatureseƫngsfrom125Ͳ140°F(52Ͳ60°C)areavailablebyseƫngswitch6toONintheSW1Dip
switch(tan
switches).Thesemodelshaveadefaultmaximumtemperatureof120°F(49°C)andanopƟon
(switch6)toincreasethemaximum temperatureto140°F(60°C).
DONOTadjusttheotherswitchesunlessspecificallyinstructedtodoso.
WARNING
x Kitchen 120°F(49°C)
x Shower 98Ͳ110°F(37Ͳ43°C)
x Bath Fill 102Ͳ110°F(39Ͳ43°C)
TemperatureSeƫngsAvailable(Fahrenheit°F)
RL75i,RL75e
98 100 102 104 106 108 110 115 120
125
*
130
*
135
*
140
*
150
**
RL94i,RL94e 185**
Celsius°C 37 38 39 40 41 42 43 46 49 52 54 57 60 66 71 85
160
**
** TheseseƫngsrequiretheMCCͲ91Ͳ2controller.WhentheMCCͲ91Ͳ2controllerisconnected,thesehigher
temperaturesareavailableonallcontrollermodelsinthesystem.UseofanMCCͲ91Ͳ2controllerina
residenƟaldwellingwillreducethewarrantycoveragetothatofa
commercialwarrantyapplicaƟon.
AlternateTemperatureSeƫngs
Adiīerentrangeoftemperatureseƫngsisavailablebyseƫngswitches2and3oftheSW2dipswitch(white
switches)toON.ThetablebelowshowstheseƫngsavailablewiththeMCͲ91Ͳ2andMCCͲ91Ͳ2controller.
AlternateTemperatureSeƫngsAvailable(Fahrenheit°F)
RL75i,RL75e
110 115 120 125 130 135 140 145 150 155 160
RL94i,RL94e
165 170 175 180 185
Celsius°C 43 46 49 52 54 57 60 63 66 68 71 74 77 79 82 85
MCͲ91Ͳ2
MCCͲ91Ͳ2
MCͲ91Ͳ1,MCCͲ91Ͳ1,MCͲ100VͲ1,andBCͲ100VͲ1controllersarenotcompaƟblewith
AlternateTemperatureSeƫngs.AlternateTemperatureSeƫngsareforcommercial
applicaƟonsonly.
DONOTusetheMCͲ91Ͳ1,MCCͲ91Ͳ1,MCͲ100VͲ1,orBCͲ100VͲ1controllers
whendip
switches2and3(whiteswitches)areintheONposiƟon.
WARNING