VCSeriesManual 21
ConnectElectricity
Donotrelyonthegasorwaterpipingtogroundthe
waterheater.AscrewisprovidedinthejuncƟonbox
forthegroundingconnecƟon.
Thewaterheaterrequires120VAC,60Hzpowerfrom
aproperlygroundedcircuit.
Ifusingthe5footlongpowercord,plug
itintoa
standard3prong120VAC,60Hzproperlygrounded
walloutlet.
Onoutdoormodels,adisconnectswitchmustbe
providedandinstalledfortheincoming120VAC
power.Itshouldbeatypethatissuitableforoutdoor
use.ChecktheNaƟonalElectricalCode,ANSI/NFPA
70
andyourlocalcodesforaproperswitchtypeto
useinyourarea.
ThewiringdiagramislocatedontheTechnicalSheet
aƩachedtotheinsideofthefrontcover.
WARNING
Donotuseanextensioncordoranadapterplugwith
thisappliance.
Thewaterheatermustbeelectricallygroundedin
accordancewithlocalcodesandordinancesor,inthe
absenceoflocalcodes,inaccordancewiththe
NaƟonalElectricalCode,ANSI/NFPANo.70.
Indoorwaterheatersareequippedwith
athreeͲ
prong(grounding)plugforyourprotecƟonagainst
shockhazardandshouldbepluggeddirectlyintoa
properlygroundedthreeͲprongreceptacle.Donot
cutorremovethegroundingterminalfr omthisplug.
ChecklistforGasandElectricity
ප
Amanualgascontrolvalveisplacedinthegas
linetothewaterheater.
ප CheckthegaslinesandconnecƟonsforleaks.
ප Conrmthatthegasinletpressureiswithin
limits.
ප Conrmthatthewaterheaterisratedforthegas
typesupplied.
ප Conrmthattheelectricityissuppliedfrom120
VAC,60Hzpowersourceandisinaproperly
groundedcircuit.
ප Anextensioncordoranadapterplughasnot
beenusedwiththewaterheater.
ප ForindoormodelsverifythatswitchNo.1inthe
SW1DIPswitch(tanswitches)hasbeenadjusted
forventlengthifnecessary.RefertothesecƟon
onMaximumVentLength.
AdjustforHighAlƟtude
OntheSW1DIPswitch(tanswitches), setswitches2
and3tothevaluesshownintablebelowforyour
alƟtude.Thedefaultseƫngfortheapplianceis0Ͳ
2000Ō(0Ͳ610m)withswitchesNo.2andNo.3inthe
OFFposiƟon.
WhentheDIP
switchisadjusted,itisnotnecessaryto
adjustthegaspressureseƫngforhighalƟtude.
AlƟtude
SW1
Switch
No.2
SW1
Switch
No.3
0Ͳ2000Ō(0Ͳ610m) OFF OFF
2001Ͳ5200Ō(610Ͳ1585m) OFF ON
5201Ͳ7700Ō(1585Ͳ2347m) ON OFF
7701Ͳ
10200Ō(2347Ͳ3109m) ON ON
AdjustforVentLength
(indoormodelsonly)
AdjustswitchNo.1intheSW1DIPswitch(tan
switches)ifrequired.RefertothesecƟon“Maximum
ventlength”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai RL94e REU-VC2837WD-US and is the answer not in the manual?

Rinnai RL94e REU-VC2837WD-US Specifications

General IconGeneral
TypeTankless
InstallationIndoor
Energy SourceNatural Gas or Propane
Flow Rate9.4 GPM
Energy Factor0.82
Gas TypeNatural Gas or Propane
Minimum Flow Rate0.4 GPM
Voltage120V
Ignition TypeElectronic
Maximum BTU199, 000 BTU
Temperature Range98°F to 140°F
Minimum BTU Input15, 000 BTU/hr
Warranty12 years heat exchanger, 5 years parts, 1 year labor