AGM - Installation and Programming Instructions 15
3. Sending Multiple SMS Commands (see page 20)
In one SMS message, you can contain several commands.
To separate between the programming commands put [:] at the end of each
programming message. In this case the SMS format will be:
[Installer code] [4 digit command 1] [=] [Data command 1] [:] [4 digit command 2]
[=] [Data command 2]:
Example: Setting MS1 and MS2 channel type (Installer code = 0200):
Installer code=0200
Setting Monitoring stations 1/2 reporting type commands: M1TY/M2TY (see page 20)
Monitoring Station1 reporting type = SMS (1)
Monitoring Station2 reporting type = GPRS (2)
0200M1TY=1:M2TY=2
4. Receiving SMS Confirmation Message (see page 20)
The SMS commands can have a confirmation reply SMS message. To achieve that add
[!] (Exclamation Mark) after the installer code. The AGM will send "0" for each
command that succeeded and "4" for each command that failed.
Important:
Space between installer code and exclamation mark is not allowed
[Installer code] [!] [4- digits command 1] [=] [Data command 1] [:] [4 digit
command 2] [=] [Data command 2]…
Example: Reporting MS1 and MS2 channel type (Installer code = 0200):
0200!M1TY=1:M2TY=2
A confirmation reply SMS message for both commands will be:
Security system:
00
5. Reading Parameter Value by SMS (see page 20)
Use the following sequence to receive the current data of the requested command:
[Installer code] [4- digits command 1] [?]
Example: Requesting information for communication format:
0200 MSCF?
Assuming that the communication format is Contact ID, the SMS reply message will be:
Security system:
0420