23
COUPLER’S ALARMS
ALARM 80 – FUSION TENSION OUT OF CONTROL
Possible cause: Power supplier is supplying tension out of machine’s limits
Solution: Check features of power supply
ALARM 100 – CURRENT IS OVER MAX VALUE ALLOWED
Possible cause: Short circuit in coupler’s resistance
Solution: Replace coupler
ALARM 200 CURRENT IS OVER MIN VALUE ALLOWED
Possible cause: One or both cables have been disconnected during fusion
Solution: Re-connect cables and re-start fusion process
Possible cause: Coupler’s resistance interrupted
Solution: Replace coupler and re-start fusion process
Possible cause: Coupler is too small (electric resistance is too big)
Solution: Use a compatible coupler
ALARM 400 COUPLER’S RESITANCE
Possible cause: Coupler’s resistance is out of limits (this may happen when using
reading/manual introduction of bar code )
Solution: Use a compatible coupler
ALARM 800 COUPLER’S RESITANCE
Possible cause: Coupler’s resistance is out of limits (this may happen when using
machine in manual introduction of tension/fusion time )
Solution: Use a compatible coupler
ALARM 1000 – SHORT CIRCUIT
Possible cause: coupler is broken
Solution: Replace coupler and re-start fusion process