Crucial health and safety guidelines for installers, emphasizing compliance with regulations and risk assessment.
Steps to take before starting installation and actions required after completion, including documentation and customer explanation.
Details technical specifications for the RM Solar S Class 10 panel, covering dimensions, materials, and performance metrics.
Provides technical specifications for the RM Solar S Class 20 panel, including dimensions, materials, and performance characteristics.
Details technical specifications for the RM Solar S Class 20 Pro panel, including dimensions, materials, and performance data.
Guidance on optimal placement of solar collectors based on roof orientation and shading for maximum performance.
Illustrations showing typical series and parallel piping configurations for RM Solar panels, including maximum panel counts.
Details the 'Sharks Fin' frame system, its suitability for tile installs, and provides step-by-step installation instructions.
Details the 'Slate Bolt' frame system, its suitability for slate installs, and provides step-by-step installation instructions.
Details the 'A Frame' system, its suitability for various applications, and provides step-by-step installation instructions.
Describes 'Tile In Roof' and 'Slate In Roof' styles for S Class 20 panels, including preparation and installation steps.
Describes the single in-roof frame style for S Class 10 panels, including preparation and installation steps.
Guidance on connections, pressure testing, and using 22mm copper pipe and compression fittings for system piping.
Details on essential insulation requirements for solar systems, including temperature resistance and flexibility.
Information on glycol as heat exchange fluid, its properties, handling, and safety precautions.
Details function, technical data, and recommended installation location for the double pump station.
Explains the expansion vessel's role, how its volume is determined, and its proper placement.
Steps before filling: covering panels, checking expansion vessel pressure, and connecting the filling pump.
Guidance on operating filling pump, bleeding air, circulating fluid, and pressurizing to 3-4 bar.
Discusses controller compatibility with cylinders and the potential need for pipestats or control stats.
Wiring diagrams for SHE-02 and Solastat controllers, showing pump, valve, and sensor connections.
Wiring diagrams for Resol BS Plus controllers, covering East/West split and 2 Store priority systems.
Detailed steps for commissioning the solar system, including pump speed, flow rate, and controller mode.
Details warranty periods for RM Solar products and the conditions for guarantee validity.
Outlines essential monthly/annual maintenance checks, including visual inspections and system testing.
Provides a template for recording service history, including engineer, company, date, and comments.