Mounting The Flashings
Mount the left hand side ashings starting with the bottom screw, use 1 x small self tapping seal
screw (4.5x35mm) at the bottom and 6 x larger sealing screws (4x80mm) up the length, ensure the
ashing runs parallel to the panel.
Mount the middle vertical ashing (for 2 or more panels) and the right hand side ashings in the
same manner.
Note: the middle apron ashing will need a 3mm pilot hole drilling on the upstand to enable the small
self tapping seal screws (5x35mm) to be tted.