2.4. Intended use
Please observe the following directives for intended use of the controllers:
The devices herein described must only be stored, fitted and operated under the conditions specified in
this documentation.
Here you are not concerned with domestic devices! They are solely intended to be used as components
for commercial or professional applications pursuant to EN 61000−3−2.
They satisfy the protection requirements of 2014/35/EU: Low Voltage Directive.
They do not constitute a machine as defined by 2006/42/EU: Machinery Directive.
A machine comprising the product must not be commissioned or put into operation for the intended use
until it has been declared to be in conformity with the EC Directive 2006/42/EU: Machinery Directive; Ob-
serve EN 60204−1.
Commissioning or starting operation for the intended use is only permitted in compliance with the EMC Di-
rective 2014/30/EU.
Use of the product in living areas may lead to EMC disturbance. The user is responsible for taking inter-
ference suppression measures.
They are optimised for operation of RNA vibratory feeders and linear feeders. Observe the limits indicated
in the technical specification.
2.5. Residual hazards
Residual hazards may remain even if all directives have been observed and protective measures taken.
Such residual hazards must be considered by the user in the risk assessment of his machine/equipment. Non-
observance may lead to severe injury and damage to property!
2.5.1. Device
Pay attention to the warning signs fitted to the device!
Description
Hazardous voltage:
Prior to commencing any work on the product check for absence of voltage on all
power connections.
Leakage current:
Make fixed installation and PE connection according to EN 60204−1!
2.5.2. Protection of the drive system
Certain device parameter settings may overheat the connected drive magnet, e.g., by prolonged operation with im-
proper boost factor.
2.5.3. Degree of protection - Protection of persons and equipment
All specifications relate to installed condition ready for operation.
All slots not used must be closed by protection caps or dummy plugs in order not to reduce the protection
against accidental contact.
Attention!
Prior to start-up make sure that the protective earth conductor is connected and in proper condi-
tion. Make the PE conductor test with approved test devices only.
Never start up despite detected damage.
Do not make any technical modifications to the device, except as described in this document.
Never start up in an incompletely installed state.
Never operate the device without the required guards in place.
Connect, disconnect or change any electrical connections only in the absence of voltage.