48
12. Cleaning
Regular cleaning will not only ensure the maximum light output, but will also allow the xture to function reliably
throughout its life.
The frequency of cleaning depends on the environment in which the xture operates: damp, smoky or particu-
larly dirty environments can cause greater accumulation of dirt on the xture housing.
The front glass cover of the head will require cleaning on a monthly basis.
A soft lint-free cloth moistened with any good glass cleaning uid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Always disconnect the xture from mains before starting any cleaning or maintenance
work.
13. Maintenance
User can do the folloving operations:
-main fuse replacement
-battery replacement
-gobo replacement
-frost replacement
Another maintenance and service operations should be carried out by trained technicians only. If you need any
spare parts, please order genuine parts from your local Robe distributor.
Replacing the fuse.
Before replacing the fuse, disconnect the xture from the mains.
1. Using a screwdriver, unscrew (anti-clockwise) the fuse holder cap from the housing of the base.
2. Remove the blown fuse from the fuse holder.
3. Place a good fuse (only the same type and rating) into the fuse holder.
4. Screw the fuse holder cap back to the housing and reconnect power.
Replacing the battery.
Before replacing the battery, disconnect the xture from the mains.
1.
Using a at-blade screwdriver, unscrew (anti-clockwise) the battery cover from the base.
2. Unscrew (anti-clockwise) the battery holder cap.
3. Remove the exhousted battery from the battery holder.
4. Place a new battery (only the same type) into the battery holder.
5. Screw the battery holder cap back.
6. Screw the battery holder cap cover back to base and reconnect power.