11-5-2
ENGINE SPEED
IS
NOT REDUCED WHEN LOAD
IS
OFF.
(1) Check the distortion of the SOLEKOID BRACKET as shown in step
11-5-1-(1).
(2)
Check the wiring
of
SOLENOID.
Check two leads from SOLENOID are securely connected.
(3)
Check the wiring
of
IDLE CONTROL
USIT.
Check all leads from IDLE CONTROL UNIT are securely and correctly connected.
(4)
Checking the SOLEKOID.
-
Measure the resistance between two leads from
SOLENOID.
I
NORMAL
RESISTANCE
I
25-31
O
If
the resistance. is larger or smaller than th-is
range, SOLENOID
..
is
defective,
Replace \vith a new one.
SOLEXOID
\
Fig.
11-17
.-
.
..
-
66
-