EasyManuals Logo
Home>Rockwell Automation>Industrial Equipment>B Series

Rockwell Automation B Series User Manual

Rockwell Automation B Series
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
Rockwell Automation Publication 520-UM001I-EN-E - July 2016 137
Programming and Parameters Chapter 3
Advanced Program Group (continued)
A562 [Find Home Freq]
PowerFlex 525 only.
Sets the maximum frequency the drive uses when “Find Home” is issued.
Values Default: 10.0 Hz
Min/Max: 0.1/500.0 Hz
Display: 0.1 Hz
PF 525
A563 [Find Home Dir]
Stop drive before changing this parameter.
PowerFlex 525 only.
Sets the direction the drive commands when “Find Home” is issued.
Options 0“Forward (Default)
1“Reverse
PF 525
A564 [Encoder Pos Tol]
PowerFlex 525 only.
Sets the “At Position” and the “At Home’ tolerance around the encoder count. The value is added to and subtracted from the target encoder unit value to create the tolerance range.
Values Default: 100
Min/Max: 1/50000
Display: 1
PF 525
A565 [Pos Reg Filter]
PowerFlex 525 only.
Sets the error signal filter in the position regulator.
Values Default: 8
Min/Max: 0/15
Display: 1
PF 525
A566 [Pos Reg Gain]
PowerFlex 525 only.
Sets the gain adjustment for the position regulator.
Values Default: 3.0
Min/Max: 0.0/200.0
Display: 0.1
PF 525

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation B Series and is the answer not in the manual?

Rockwell Automation B Series Specifications

General IconGeneral
BrandRockwell Automation
ModelB Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals