13 Parameters menu
PARAMETER
PARAMETER
VALUE
$
Enable RS485 serial communication (MASTER-SLAVE)
Enabling serial communication permits the synchronised control of two opposing automation systems.
ExampleEGSQQERHWMKREPVIGIMZIHF]1%78)6EYXSQEXMSRW]WXIQEPWSSTIRWXLI70%:)EYXSQEXMSR
system.
Disabled.
SLAVE automation system.
MASTER automation system. When the MASTER automation is enabled, the message 6U&+
C485
illuminates on the display for a few seconds. If the SLAVE automation system is
detected correctly, C485 illuminates.
$
Barrier model and the length of the boom selection
WARNING! An incorrect setting may cause severe damage or injury.
Use the standard parameter values indicated in the table in relation to the boom length selected.
Parameter
AG/004
boom up to 3 m
STANDARD VALUE
KB/004
BI/004HP
AG/004
boom from 3 m to 4.5 m
KB/004
BI/004HP
AG/006
boom from 4.5 m to 6 m
KB/006
BI/006
BI/004 boom up to 3 m
BI/004 boom from 3 m or 4 m
BI/008 boom up to 8 m
$
Automatic closing after time pause (from barrier completely open position)
N.B.: This parameter is not visible for the SLAVE barrier, and if the value of parameter = , or .
Disabled.
From 1 a 15 automatic closure attempts after activation of photocells.
Once the number of attempts set is reached, the barrier remains open.
8LIFEVVMIVXVMIWXSGPSWIMRHIƼRMXIP]
$
Automatic closing after mains power outage
N.B.: This parameter is not visible for the SLAVE barrier.
Disabled. The barrier does NOT close automatically when mains power is restored.
Enabled. If the barrier is NOT completely open, when mains power is restored, the barrier closes after a
WIGSRHTVIQERSIYZVI[EVRMRKWMKREPPIH[MXLXLIƽEWLMRKPMKLXMRHITIRHIRXP]SJXLIZEPYIWIX[MXL
parameter $).