EN
82

Normally not powered. The electric lock is powered for 1,5 s at the start of the opening manoeuvre to
allow the barrier to open.

Magnetic "ventouse" electric lock normally powered when the barrier is completely closed. Not powered
when the barrier is moving or completely open

Obstacle detection function setting (crush prevention)
The barrier reopens if the obstacle detection system is activated during a closing manoeuvre.
During opening manoeuvres, the barrier is reversed by the obstacle detection system only if the obstacle
MWHIXIGXIH[MXLMRXLIƼVWXqSJXLIQERSIYZVI
The maximum number of automatic closing attempts is set by parameter .
N.B.: Available values may be limited by the setting for parameter $.

= minimum activation time (maximum sensitivity)... = maximum activation time (minimum sensitivity).

The barrier remains stationary against the obstacle for a maximum time of 5 s before reversing.

Setting opening start acceleration

Setting closure start acceleration

= the barrier accelerates rapidly at start of manoeuvre ... = the barrier accelerates slowly and pro-
gressively at start of manoeuvre.
N.B.: Available values may be limited by the setting for parameter $.

Setting opening speed (%)

Setting closure speed (%)

= 10% minimum speed ... = 100% maximum speed.
N.B.: Available values may be limited by the setting for parameter $.
Approach speed setting
This parameter sets the motor speed when approaching the barrier open/closed stop.

= 10 motor revolutions per minute (RPM) ... = 100 motor revolutions per minute (RPM).

Opening approach distance setting

Closing approach distance setting

from 0,5 to 3 of turns performed by the motor at speed set with parameter .
N.B.: Available values may be limited by the setting for parameter $.
Number of automatic closure attempts after activation of sensing edge or ob-
stacle detection (crush protection)

No automatic closure attempts.

From 1 to 3 automatic closure attempts.
Automatic closure is only performed if the barrier is completely open.
Set a value equal to or lower than the value set for parameter $.

Photocell mode for barrier opening (FT)
N.B.: this parameter is not visible if the value of parameter  = ,  or .

DISABLED. Photocell is not active or not installed.

STOP. The barrier stops and remains stationary until the next command is received.

IMMEDIATE REVERSE. The barrier reverses immediately if the photocell is activated during opening manoeuvre.

TEMPORARY STOP. The barrier stops and remains stationary as long as the photocell is obstructed. The
barrier resumes opening when the photocell is cleared.

DELAYED REVERSE. The barrier stops if the photocell is obstructed. The barrier closes when the photocell
is cleared.

Photocell mode for barrier closure (FT)
N.B.: this parameter is not visible if the value of parameter  = ,  or .

DISABLED. Photocell is not active or not installed.

STOP. The barrier stops and remains stationary until the next command is received.

IMMEDIATE REVERSE. The barrier reverses immediately if the photocell is activated during closing manoeuvre.

Other manuals for Roger Technology CTRL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roger Technology CTRL and is the answer not in the manual?

Roger Technology CTRL Specifications

General IconGeneral
BrandRoger Technology
ModelCTRL
CategoryControl Unit
LanguageEnglish

Related product manuals