EasyManuals Logo

Roger Technology CTRL Instruction And Warnings For The Installer

Roger Technology CTRL
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
EN
83

TEMPORARY STOP. The barrier stops and remains stationary as long as the photocell is obstructed. The
barrier resumes closing when the photocell is cleared.

DELAYED REVERSE. The barrier stops if the photocell is obstructed. The barrier opens when the photocell
is cleared.
Photocell (FT) mode with barrier closed
N.B.: this parameter is not visible if the value of parameter  = ,  or  or if $ = , , or .

If the photocell is obstructed, the barrier cannot open.

The barrier opens when an open command is received, even if the photocell is obstructed.

The photocell sends the barrier open command when obstructed.

Enable close command 6 s after activation of photocell (FT)
N.B.: This parameter is not visible if $ or $ is set, and if value of parameter  = ,  or .

Disabled.

Enabled. When the photocell barrier FT is crossed, a close command is sent 6 seconds later.

Motor stop distance setting
The motor brake function is activated each time a stop is requested by a user command or by activation
of the photocells.
Set a value that will prevent collision with objects or persons due to the inertia of the boom.

01= rapid braking/smaller stopping distance ...
10= gentle braking (soft-stop)/greater stopping distance (NOTEVIGSQQIRHIHWIXXMRKJSVFEVWPSRKIVXLERQ
N.B.: Available values may be limited by the setting for parameter $.
Installation position of barrier relative to gateway (seen from interior side)
For installations with two opposed barriers, this setting must be made for the MASTER barrier. The SLAVE
barrier recognises its position automatically.
N.B.: every time the installation position is changed by altering parameter , the display shows a
position data request message GDWD. Press the PROG key until $33 appears on the display, then repeat
XLIEGUYMWMXMSRTVSGIHYVIWIIƼKERHGLETXIV

Barrier installed on the left, viewed from the inspection cover side. With passage opening on the right.

Barrier installed on the right, viewed from the inspection cover side. With passage opening on the left.

7IRWMRKIHKI'37GSRƼKYVEXMSR

Sensing edge NOT INSTALLED.

NC contact (normally closed). The barrier reverses only when closing.

Contact with 8k2 resistor. The barrier reverses only when closing.

6EHMSGLERRIPGSRƼKYVEXMSR46

6EHMSGLERRIPGSRƼKYVEXMSR46

STEP MODE.

PARTIAL OPENING.

OPENING.

CLOSING.

STOP.

78)413()[MXLGSRƼVQEXMSRJSVWEJIX]
(1)
.

4%68-%034)2-2+[MXLGSRƼVQEXMSRJSVWEJIX]
(1)
.

34)2[MXLGSRƼVQEXMSRJSVWEJIX]
(1)
.

'037)[MXLGSRƼVQEXMSRJSVWEJIX]
(1)
.
(1)
8STVIZIRXFEVVMIVQERSIYZVIWGEYWIHF]EGGMHIRXEPP]TVIWWMRKEVIQSXIGSRXVSPFYXXSRGSRƼVQEXMSRMWVIUYMVIHXSIREFPIXLIGSQ-
QERH)\EQTPITEVEQIXIVW e WIX
4VIWWMRKXLI',%FYXXSRSRXLIVIQSXIGSRXVSPWIPIGXWXLIWXITQSHIJYRGXMSR[LMGLQYWXFIGSRƼVQIH[MXLMRWIGSRHWF]
pressing CHB on the remote control. Press CHB to activate partial opening.
*PEWLMRKPMKLXYTTIVGSZIVPMKLXWJVIUYIRG]GSRƼKYVEXMSR

8LIJVIUYIRG]MWWIXIPIGXVSRMGEPP]JVSQXLIƽEWLMRKPMKLXYRMX

Other manuals for Roger Technology CTRL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roger Technology CTRL and is the answer not in the manual?

Roger Technology CTRL Specifications

General IconGeneral
BrandRoger Technology
ModelCTRL
CategoryControl Unit
LanguageEnglish

Related product manuals