Test Report R&S CMU
1100.4903.82 1.34 E-5
Item
No.
Description
Measure-
ment
to section
Min. Actual Max.
Measurement
uncertainty
Unit
RX inherent spurious response at RF2,
f
IN
= 2200 MHz, R&S CMU frequency =
1778.4575 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 1812.056667 MHz,
R&S CMU frequency = 1250 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 1681.5425 MHz,
R&S CMU frequency = 1680 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 1468.085 MHz,
R&S CMU frequency = 1250 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 1683.085 MHz,
R&S CMU frequency = 1680 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 1943.085 MHz,
R&S CMU frequency = 2200 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 978.7233333 MHz,
R&S CMU frequency = 1250 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 1295.39 MHz,
R&S CMU frequency = 2200 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 1210.843333 MHz, R&S CMU
frequency = 1210.743333 MHz
–50 dBc
RX inherent spurious response at RF2,
f
IN
= 1262.31375 MHz,
R&S CMU frequency = 1260 MHz
–50 dBc
RX inherent spurious response at RF4
IN, f
IN
= 968.0575 MHz,
R&S CMU frequency = 60 MHz
–50 dBc
RX inherent spurious response at RF4
IN, f
IN
= 1200 MHz,
R&S CMU frequency = 291.9425 MHz
–50 dBc
RX inherent spurious response at RF4
IN, f
IN
= 645.3716667 MHz, R&S CMU
frequency = 60 MHz
–50 dBc
RX inherent spurious response at RF4
IN, f
IN
= 1200 MHz,
R&S CMU frequency = 891.9425 MHz
–50 dBc
RX inherent spurious response at RF4
IN, f
IN
= 1936.115 MHz,
R&S CMU frequency = 60 MHz
–50 dBc
RX inherent spurious response at RF4
IN, f
IN
= 2200 MHz,
R&S CMU frequency = 191.9425 MHz
–50 dBc
RX inherent spurious response at RF4
IN, f
IN
= 1671.5425 MHz,
R&S CMU frequency = 1250 MHz
–50 dBc
RX inherent spurious response at RF4
IN, f
IN
= 2200 MHz, R&S CMU
frequency = 1778.4575 MHz
–50 dBc