R&S FSH Distance-to-Fault Mode (R&S FSH-K41)
Vector Voltmeter (R&S FSH-K45)
Operating Manual 1173.6275.12 - 30 214
7 Distance-to-Fault Mode (R&S FSH-K41)
Equipped with firmware option R&S FSH-K41 (order no. 1304.5612.02), you can
perform distance-to-fault measurements with your R&S FSH.
The distance-to-fault (DTF) mode provides functionality to measure cables for
mechanical defects in the system that cause a deterioration of the transmission quality.
The figure below shows some typical defects in a transmission system, including
defects on the cable.
The R&S FSH provides the necessary functionality to test the system equipment for its
characteristics and identify faults when it is being installed or maintained.
Reflection Measurements on page 216
Distance to Fault Measurements on page 217
Spectrum Measurements on page 217
Test setup
A typical test setup to test cables and antennas includes the R&S FSH, an RF cable
(e.g. R&S FSH-Z320, order no. 1309.6600.00), a calibration standard (R&S FSH-Z28
or R&S FSH-Z29, order no. 1300.7804.03 and 1300.7504.03) and the cable under test.
Cable and antenna tests also require a tracking generator and VSWR bridge. The
tracking generator transmits a reference signal through the internal VSWR bridge to
the test port.
Connect the RF cable to the RF input (port 1 or 2).
Connect the test cable to the RF cable.