R&S FSP  Troubleshooting 
1164.4556.82 3.77  E-1 
Troubleshooting -  Loading Module EEPROMs 
• Error: Data of modules cannot be read. 
Normal action  Error and error cause 
On booting the instrument all calibration data 
required must be written into the RAM of the 
computer. The calibration data of a module is read 
from the EEPROM in the case of a cold start, 
otherwise from the associated binary file. 
In the case of a cold start, it is checked for each 
module identified by the software whether the 
EEPROM can be read. 
 
If reading at the desired address is not possible, 
the software assumes that the module is not 
available.  
For modules that must always be available (e.g. 
IF filter) an error message will be output: 
Error reading EEPROM of IF Filter 
The calibration data are then read from the file 
pertaining to the module (e.g. iffilt.bin). 
If error-free reading of the binary file is not 
possible either, an error message is output again.
Error reading file of IF Filter 
If reading at the address of an optional module is 
not possible, this module is marked as not 
available in the module array for storage of the 
module information.  
If the file pertaining to the non-available module 
does exist, it is assumed that upon the last 
successful booting the module was available but 
has been removed meanwhile. The file with the 
calibration data of the module is erased. 
Moreover the data collected during the last 
calibration are invalid and only saved as a 
backup copy on the hard disk 
 
If reading at the address of a module is possible 
but the contents of the data block faulty (e.g. 
check sum of header block incorrect), the 
calibration data of the respective module are 
read from the associated file. The firmware 
assumes that the module is available. 
Error reading EEPROM of IF Filter