Transmitter System R&S TLx9
R&S
®
TLx9
53System Manual 2506.5060.02 ─ 03
DVB-T DVB-T2 ISDB-T
(B)
Cooling system Air-cooled
Max. installation alti-
tude
2000 m (above sea level)
Operating temperature +1 °C to +45 °C (Technical data guaranteed)
Permissible tempera-
ture
0 °C to +50 °C (Technical data not guaranteed
Maximum relative
humidity
95 % non-condensing
Dust conditions Pollution degree 2 (IEC 60664-1)
(with air filter: pollution degree 3)
Air Filter Compliant with DIN EN 779 G2
Environmental class ETSI EN 300-019-1-3
Interior
, in acc. with 3.2, with limited temperature range, non-condensing
Immunity to radiated
interference
Up to 10 V/m
Power supply
V
oltage supply 100 to 240 V AC ± 10 %
AC supply frequency 50 Hz to 60 Hz ± 10 %, single phase
Power consumption
200 W DTV average power: ~800 W
100 W DTV average power: ~465 W
50 W DTV average power: ~260 W
25 W DTV average power: ~180 W
15 W DTV average power: ~150 W
10 W DTV average power: ~135 W
5 W DTV average power: ~120 W
Immunity
To fast transients and
burst in line with IEC
61000-4-4
±2 kV (AC mains)
±1 kV (signal inputs)
To surges in line with
IEC 61000-4-5
Symmetrical ±1 kV (e. g. L-N)
Asymmetrical ±2 kV (e. g. L-PE, N-PE)
Mechanical resistance
Design and Function – R&S TLx9