R&S TLx9 Interface Description
R&S
®
TLx9
80System Manual 2506.5060.02 ─ 03
Signal
Name/Description
Direction Value range Connection
point
Remarks
MDI2[4] Output
 
X36.2.A53 CAM data in
MDI2[5] Output
 
X36.2.A54 CAM data in
MDI2[6] Output
 
X36.2.A55 CAM data in
MDI2[7] Output
 
X36.2.A56 CAM data in
MCLKO2 Input
 
X36.2.A57 CAM data out
RESET2 Output
 
X36.2.A58
 
WAIT2 Output
 
X36.2.A59
 
INPACK2 Output
 
X36.2.A60
 
REG2 Output
 
X36.2.A61
 
MOVAL2 Input
 
X36.2.A62 CAM data out
MOSTRT2 Input
 
X36.2.A63 CAM data out
MDO2[0] Input
 
X36.2.A64 CAM data out
MDO2[1] Input
 
X36.2.A65 CAM data out
MDO2[2] Input
 
X36.2.A66 CAM data out
CD2[2] Output
 
X36.2.A67
 
GND Output
 
X36.2.A68
 
A.2.5  1+1 ASI Distribution Board
Table A-38: X20 – IN: BNC jack 75 
Ω
Signal
Name/Description
Direc-
tion
Value range Connection
point
Remarks
ASI_IN1 Input U
ss
 = 400 mV
ss
 to 800
mV
19.39 to 270 Mb/s
X20.1 ASI input 1
GND Bidirec-
tional
0 V X20.2 GND / shield
Table A-39: X21 – IN: BNC jack 75 
Ω
Signal
Name/Description
Direc-
tion
Value range Connection
point
Remarks
ASI_IN2 Input U
ss
 = 400 mV
ss
 to 800
mV
19.39 to 270 Mb/s
X21.1 ASI input 2
GND Bidirec-
tional
0 V X21.2 GND / shield
Option Board Interfaces