R&S TLx9 Interface Description
R&S
®
TLx9
64System Manual 2506.5060.02 ─ 03
Signal
Name/Description
Connection point Remarks
RECEIVER X70 Receiver input for Exciter / GapFiller
Board
RF Switch X83 Interface to control a mechanical RF
switch
A.1.2  Description
Table A-1: X1 - Mains
Signal Name/Description Direction Value range Connection
point
Remarks
L1 Input 100 to 240 V AC ± 10 % X1.L Mains connection
N Input 0 V X1.N Mains connection
PE Input 0 V X1.PE Mains connection
IEC (standard with integrated fuses 10 A) for RF output power ≤ 100W OFDM.
EC11 (high current up to 16 A, no integrated fuse) for RF output power 200 W OFDM.
 
T
able A-2: X2 - LAN Remote: 8-pin RJ-45 socket
Signal
Name/Description
Direction Value range Connection
point
Remarks
BI_DA+ Bidirec-
tional
V
odif
f
 = 670 to 820 mV
ss
X2.1
 
BI_DA- Bidirec-
tional
V
idiff
 = 750 mV
ss
 typ.
X2.2
 
BI_DB+ Bidirec-
tional
V
odiff
 = 670 to 820 mV
ss
X2.3
 
BI_DB- Bidirec-
tional
V
idiff
 = 750 mV
ss
 typ. X2.4
 
BI_DC+ Bidirec-
tional
V
odiff
 = 670 to 820 mV
ss
X2.5
 
BI_DC- Bidirec-
tional
V
idiff
 = 750 mV
ss
 typ. X2.6
 
BI_DD+ Bidirec-
tional
V
odiff
 = 670 to 820 mV
ss
X2.7
 
BI_DD- Bidirec-
tional
V
idiff
 = 750 mV
ss
 typ. X2.8
 
Base unit and Exciter / GapFiller Board Interfaces