R&S TLx9 Interface Description
R&S
®
TLx9
66System Manual 2506.5060.02 ─ 03
Table A-5: X12 - Terminal Supply: 4P connector
Signal Name/Description Direction Value range Connection
point
Remarks
TERMINAL SUPPLY Output 12 V DC ± 1,5 V X12.1 I
max.
= 1.6 A
GND Bidirec-
tional
0 V X12.2
USB SUPPLY Output 5 V DC ± 0,5 V X12.3 I
max.
= 1 A
GND Bidirec-
tional
0 V X12.4
Table A-6: X14 - USB: USB connector type A
Signal Name/Description Direc-
tion
Value range Connection
point
Remarks
+5V USB Output
X14.1
USB Data- Bidirec-
tional
X14.2
USB Data+ Bidirec-
tional
X14.3
GND Bidirec-
tional
X14.2 GND / shield
Table A-7: X20 – TS1 IN: BNC jack 75
Ω
Signal
Name/Description
Direc-
tion
Value range Connection
point
Remarks
TS1 Input ASI / SMPTE310M X20.1
GND Bidirec-
tional
0 V X20.2 GND / shield
Table A-8: X21 – TS2 IN: BNC jack 75
Ω
Signal
Name/Description
Direc-
tion
Value range Connection
point
Remarks
TS2 Input ASI / SMPTE310M X21.1
GND Bidirec-
tional
0 V X22.2 GND / shield
Table A-9: X22 – TS Monitor: BNC jack 75
Ω
Signal
Name/Description
Direc-
tion
Value range Connection
point
Remarks
TS_MON Output ASI / SMPTE310M X22.1
GND Bidirec-
tional
0 V X22.2 GND / shield
Base unit and Exciter / GapFiller Board Interfaces