5.3. Installation environment & operating location
When selecting a suitable place for your kiln, please note the following guidelines and prepare the kiln environment
accordingly:
The kiln is not intended for outdoor installation outside of closed rooms.
Place the kiln on an even surface.
The distance to the walls should be at least 50 cm on each side.
The floor, ceiling insulation, walls, dividing walls, panelling, etc. must be made of flame resistant material.
Make sure that the kiln environment can be properly ventilated. Otherwise a ventilation system must be
installed. Please consult a qualified ventilation specialist.
Permissible ambient conditions:
Permissible ambient temperature = -5 °C to +30 °C
Relative humidity = less than 80% (non-condensing)
Firing chamber atmosphere = oxidising
5.4. Assembly of kiln
Step
Action required
Illustration
1
Check the enclosed accessories first (figure 1):
3 cordierite blocks
(6 blocks for TE 165/250 and TE 300)
1 ceramic tube for exhaust air
2 sealing plugs
1 plastic cap for kiln stand
1 spare part for kiln stand
1 exhaust air socket and fixing screws
1 panel for mounting the controller and fixing screws
(not shown)
2
You will also find enclosed the controller as well as two
manuals for the controller and the kiln.
3
First screw the mounting panel into the holes indicated
on the cover bolt (obey the enclosed assembly
instructions).
4
Take the ceramic tube out of the box and plug it onto
the exhaust air opening on the left side of the kiln.