5.9. Notes on power connection (residual current protective device [RCD])
If you intend to operate the kiln in workshops or laboratories, a separate power supply with fuse protection must be
installed by a qualified electrician. Residual current protective devices (RCD) carrying a tripping current of 0.03A
(such as that used in damp rooms in flats) tend to trip early due to the high humidity of the rooms or fired goods. A
larger sized RCD can be selected (we suggest 0.3A) provided that the respective circuit is used only for the kiln. If
this cannot be guaranteed, a fixed power connection must be provided.
6. General notes on operation
6.1. Operation of the controller
Please read the kiln control instruction manual carefully. The kiln is ready for operation after it has been connected
to the mains supply and the controller.
Typical firing curve of a controller:
6.2. Correct operation during firing
Do not place flammable objects near the kiln.
The kiln may only be used in a well-ventilated room.
In order to guarantee safe operation, the kiln may be only operated up to an environmental temperature of
+30°C.
The kiln must be placed in a free-standing position in the room. Make sure that the heat release is not
blocked.
Do not place any objects on top of or around the kiln.