15 | Automate
™
Programming Instructions | AX30/AX50 External Shade Motor ROLLEASE ACMEDA
5.4 Delete Upper/Lower Limits
Press P2 on controller Press DOWN on controller Press P2 on controller
Motor Response Motor Response Motor Response
Move shade to Upper/Lower Limits
5.4.1 Activate/Deactivate Upper Limit Fabric Tension
Press P2 on controller Press STOP on controller Press UP on controller
ACTIVATE:
Motor Response Motor Response Motor Response
DEACTIVATE:
Upper limit fabric tension is deactivated by default.