Reference Manual
00809-0100-4825, Rev BB
August 2005
Rosemount 248
B-2
K6 CSA Intrinsically Safe, Explosion-Proof, and Class I, Division 2.
Combination of I6 and Explosion-Proof for Class I, Division 1, Groups B,
C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1
hazardous locations, when installed in accordance with Rosemount
drawing 00644-1059.
Suitable for Class I, Division 2, Groups A,B, C, and D.
Ambient Temperature Limit: –50 to 85°C
European Approvals
(1)
CENELEC Approvals
I1 CENELEC Intrinsic Safety
Certificate Number: BASEEFA03ATEX0030X
ATEX Marking: II 1 G
1180
EEx ia IIC
Temperature Codes:
T5 (–60 ≤ T
amb
≤ 80 °C)
T6 (–60 ≤ T
amb
≤ 60 °C)
Special Conditions for Safe Use (X):
The apparatus must be installed in an enclosure which affords it a degree of
protection of at least IP20. Non-metallic enclosures must have a surface
resistance of less than 1 GOHM; light alloy or zirconium enclosures must be
protected from impact and friction when installed.
E1 CENELEC Flame-Proof Approval
Certificate Number: KEMA99ATEX8715
ATEX Marking: II 2 G
1180
EEx d IIC
Temperature Codes:
T6 (–40 ≤ T
amb
≤ 65 °C)
N1 CENELEC Type n
Certificate Number: BAS00ATEX3145
ATEX Marking: II 3G
EEx nL IIC
Temperature Codes:
T5 (–40 ≤ T
amb
≤ 70 °C)
NC CENELEC Type n Component
Certificate Number: BASEEFA03ATEX0032U
ATEX Marking: II 3G
EEx nA IIC
Temperature Codes:
T5 (–60 ≤ T
amb
≤ 80°C)
T6 (–60 ≤ T
amb
≤ 60°C)
ND CENELEC Dust Ignition-Proof
ATEX Marking: II 1 D
1180