EasyManua.ls Logo

Rosenbauer FLF 15000 PANTHER - Trouble Shooting; Pump Problems and Solutions

Rosenbauer FLF 15000 PANTHER
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page - 115 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
FAILURE PROBABLE CAUSE CORRECTIVE ACTION
Pump does - Pump not engaged Engage pump
not operate - Priming pump disengaged Engage priming pump
- Suction lift to high Reduce suction lift
- Suction strainer not under water Place suction strainer under water
- Suction strainer obstructed Clean suction strainer
- Suction hose defective or gasket Change suction hose,
not installed properly or install gaskets properly or
damaged change them
- Suction screen obstructed Clean suction screen
- Drafting valve closed Open drafting valve
- Drain valve not closed Close drain valve
- Discharge valve leaks due to Clean discharge valve
impurity or gasket damage (rinse with clean water) or
change gasket
- V-belt oily or turned-off Clean resp. change the V-belt
Poor priming - Inlet- and/or outlet valves of the Change inlet- and/or outlet
performance priming pump are damaged valves
Pump is noisy - Suction lift too high Reduce suction lift
and vibrates - Pump cavitates Reduce engine speed and nozzle
diameter, clean suction strainer
and suction screen
Poor pump - Suction strainer is obstructed Clean suction strainer
performance - Suction hose defective, Change suction hose,
gaskets not properly installed install gaskets properly
or damaged or change them
- Suction screen obstructed Clean suction screen
- Engine does not perform Check engine
- Discharge valves not fully opened Open discharge valve
Trouble Shooting
ATTENTION !
If any assistance is necessary do not hesitate to call your nearest "Rosenbauer" representative or contact the
"Rosenbauer" Service Department.
Problems and their Solutions
Propulsion problems: please refer to manufacturers manual
Pump problems: please refer to the list below; this list is not a complete list,