EasyManua.ls Logo

Rosenbauer FLF 15000 PANTHER - Page 59

Rosenbauer FLF 15000 PANTHER
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page - 59 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Air Crash Mode
Bumper turret - operation with foam
- Operate pump in automatic mode (base setting):
The integrated pilot lamp in switch (S54) is off.
- Engage the pump:
Please refer to the "Engaging the Pump" chapter.
- When the pump is engaged the following program starts:
The water tank suction valve opens automatically.
The priming pump is engaged automatically until a pressure
of 2 bar is achieved (visible on water pressure gauge (P6))
and the engine speed increases.
The pump icon (J1) illuminates blue as long as the priming
pump is engaged.
After achieving a pressure of 2 bar the engine speed decrease
to idle.
- Preselect the foam compound tank suction valve:
Press switch (S18), the integrated pilot lamp blinks.
- If required change the foam proportioning rate:
Press switch (S14/1) if 3% or (S14/3) if 8% is required
otherwise 6% foam proportioning rate will be created.
- Press "START"-switch (S218).
The turret automatically moves to the pre-programmed
attack position.
The position LED (H94) illuminates when the turret has
reached the attack position.
- Direct the turret to desired position by using joystick (19).
- Open turret discharge line and foam compound tank suction
valve:
Press switch (S80) as long as water/foam discharge is
desired or
for permanent discharge press a switch (S80p). *
The pilot lamp in switch (S18) illuminates.
Pump speed is increased automatically to full speed, as soon
as the turret discharge valve is opened.
- To generate spray press switch (S81s) or for full jet press switch
(S81f). This can be done whilst fire fighting.
S218 H94
S80p
S81s
S80
19
S81f
8%
3%
S14/3
xx,x bar
xxxx U/min
x %
xx °C
xxx h
J1
S54
S14/1
S80p
S18
P6