Connecting between MD-N33 and AC-215
38 AC-215 Installation Manual
b. Change the "number of dial attempts" as needed.
c. In the Additional dialing string options field, for most applications,
the default dialing string of AS-525 is enough.
The dialing string is displayed in the window.
Adding or editing dialing string is allowed by clearing the "Use
default" checkbox and typing the AT command in the dialing string
window.
d. In the “Dialing schedule” dropdown, select the proper time zone.
The disconnecting condition can be chosen: "Disconnect by schedule
end" or "Disconnect on upload complete". (It is allowed when the
selected time zone is different than the default time zones (Always &
Never).
3. In the Settings section:
For most applications, the default initialization string of AS-525 is enough.
The initialization string is displayed in the window.
Adding or editing initialization string is allowed by clearing "Use default"
and type the AT command in the "Initialization string" window.
4. Connect the PC modem to the PC via the selected com port and click
Apply to initialize the PC modem.
5. Click OK for the successful initialization.
If a failure message appeared, check the modem connections and repeat
the last steps.