Programming
48 AC-F/G4x Series Installation and Programming Manual
opens; if the door closes, the auxiliary relay closes. When a valid
code is entered, a countdown for maximum Shunt time, as
defined by the auxiliary setting, begins; if the door is not closed
before the maximum Shunt time, the alarm is triggered.
5.9.7 Auxiliary Mode 6
Auxiliary input function: Door Monitor
Auxiliary output activated by: Forced entry
For example, in auxiliary mode 6, the controller can trigger the
auxiliary relay if the door has been forced. If the Siren Settings is
enabled, the siren is activated.
In this mode, the auxiliary input functions as a door monitor
switch and is wired to the magnetic contact switch on the door.
The auxiliary relay is to be wired to the alarm system. If the door
is forced open, the controller waits for the period of the Forced
Door Delay time to elapse and then it activates the auxiliary
relay. The auxiliary setting sets the forced door delay period.
5.9.8 Auxiliary Mode 7
Auxiliary input function: Door Monitor
Auxiliary output activated by: Door Ajar (door held open)
For example, in Auxiliary Mode 7, the controller can trigger the
auxiliary relay, if it detects that the door has been held open
(ajar) too long. In this mode the auxiliary input functions as a
door monitor switch and is wired to the magnetic contact switch