Programming
60 AC-F/G4x Series Installation and Programming Manual
8.
Perform one of the following:
Enter the PIN code of the Primary code
belonging to the user you want to
delete.
Present the user card of the Primary code belonging to
the user you want to delete.
The left LED flashes red.
9.
Enter your 4-digit Programming code to confirm the
deletion.
If the Programming code is valid, you hear three beeps and
the unit returns to Normal mode.
If the Programming code is invalid, you hear a long beep
and the unit returns to Normal mode.
5.14
Relay Codes Assignment
When a Primary code is enrolled for any user, the user is
authorized to activate the Lock Strike relay. However, different
user codes may be set to operate the auxiliary relay instead or
operate both the Lock strike and auxiliary relay. Assignment of
such codes is achievable for any valid user code entered in the
controller.