Controller Operation
42 AYC-F/Gx4 Series Installation and Programming Manual
3. Construct a code using the following
instructions:
First digit
For Fail Secure Operation, the first digit should be 0.
For Fail Safe Operation the first digit should be 1.
Second digit
Siren Time in minutes (19, 0 disabled)
Third and fourth digits
Enter the number of seconds (from 1 to 99) that you want
the Lock Strike to be released.
For example, 0312 means a Fail Secure Operation consisting of a
3-minute siren and a 12-second Lock Strike release time.
You hear three beeps.
The system returns to Normal mode.
The default value is 0004, which corresponds to Fail Secure
operation, no siren, and 4-seconds Lock Strike release time.
5.9.9 Defining the Auxiliary Input and Output
The default auxiliary setting is 2004.
To define the auxiliary input and output:
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The left LED flashes green.
Green
Green
Green
Green

Table of Contents

Other manuals for Rosslare AYC-F/Gx4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-F/Gx4 Series and is the answer not in the manual?

Rosslare AYC-F/Gx4 Series Specifications

General IconGeneral
BrandRosslare
ModelAYC-F/Gx4 Series
CategoryController
LanguageEnglish

Related product manuals