5
6
4. Technical specifications
4.1 Technical data
Operation.........................................electro-hydraulic
Carrying Capacity.............................3000kg
Lift time............................................. 30sec.
Lowering time................................... 20sec.
Noisy level........................................<74 db
Weight..............................................530 kg. approx.
Working temperature........................+7°C / +38°C
Installation requirements: enclosed area.
4.2 Motor
Power................................................2.6 KW
Voltage..............................................230V/400V 3ph
Frequency.........................................50/60 Hz
Poles.................................................4
Speed................................................1410/1680 rpm
Insulation class..................................F
Absorption........................................15.1/8.7 A-50Hz
Service..............................................S3 10Min
4.3 Hydraulic control unit
Type...............................................Gear pump
Displacement................................. 8 cm /round
Peak pressure................................140 bar
Relief valve ....................................145 bar
4.4 Oil
Use Dexron III ATF, or hydraulic fluid that meets
ISO32 specifications. Remove fill breather cap and
add ten quarts of fluid. Turn power to on and ensure
the disconnect switch and emergency stop buttons
are in the "ON" position.
mm(without load)
990mm(with full load)
1000
<
<
3
11.1/6.4 A-60Hz