TROUBLESHOOTING
Troubleshooting
Description
Lift Stops Short Of Full Rise
Lift Chatters
Cylinder Groaning
Anchors Will Not Stay Tight
Lift Going Up Unlevel
Lift will not raise off of latches.
Possible
Cause
Low Oil Level
Low Oil Level
1. Air in hydraulic system.
2. Dry hydraulic cylinder rod
1. Holes Drilled Oversize
2. Concrete Floor Not Thick Enough
3. Concrete Floor Not Strong Enough
1. Leveling system components not
operating properly
2. Lock obstructed
3. Pinched Or Chafed Position Sensor
Cable
1. Motor, pump, or cylinder failure.
Remedy
1. Refill reservoir per the install
instructions and with the
recommended oil grade.
1. Check for leaks.
2. Refill reservoir per the installation
instructions and with the recom-
mended oil grade.
1. Cycle lift to full stroke.
2. Spray with silicon lubricant.
1. Relocate lift using a new bit to
drill holes. Reference installation
instructions for proper anchor-
ing method and minimum spacing
requirements.
2. Break out old concrete and re-pour
per lift installation instructions.
3. Break out old concrete and re-pour
per lift installation instructions.
1. Re-calibrate per installation in-
structions.
2. Check obstructions/locks- the lift
must be raised manually to move
the lift to within operating limits .
Refer to Manually raising and low-
ering runways.
3. Check for pinched or chafed posi-
tion sensor cable. Use a continu-
ity tester to check signal wires to
shield fault then each conductor to
another for a fault. Replace cable if
damaged.
1. Contact lift manufacturer’s Customer
Service.