Display screen | 2.8-inch full-view TFT display |
---|---|
LCD resolution | 320×240 |
Colour palette | Rainbow, iron oxide red, cold col our, black & white, white & black |
Temperature measurement range | -20℃ to 300℃ (-4°F to 572°F) |
Emissivity | Adjustable from 0.01 to 1.00 |
Measurement accuracy | ±2℃/±2% (whichever is greater) |
Infrared image resolution | 220×160 |
Visible image resolution | 35200 pixel |
Field angle | 35°×26° |
Focal distance (shortest) | 0.15m |
Thermal sensitivity | 0.07℃ |
Frame rate of thermal images | 9Hz |
Focus mode | Fixed |
Wavelength coverage | 8-14um |
Storage capacity | Built-in memory 3GB |
File format | JPG |
Setting command | Unit, language, date, time, information |
Language | English & French |
USB | Micro USB 2.0 |
Power supply | Built-in chargeable 18650 battery Detachable |
Automatic power-off time | Selectable: 5 minutes/20 minutes/ not power off automatically |
Working time | 2-3 hours |
Product size | 96mm×72mm×226mm |
---|---|
Product weight | 389g |
Use Micro USB cable for charging. Ensure the product is turned off before charging.
Do not charge for over 24 hours. Charge for two hours every three months for longevity.
Marks colours corresponding to relative temperature from low to high.
Press and hold the power button for 3 seconds to turn the camera on or off.
Press trigger to capture. Confirm photo save or deletion using menu/enter keys.
Details emissivity adjustment and its importance for accurate temperature measurement.
Outlines four surface measurement modes for setting emissivity values.
Explains how to apply emissivity settings and the custom option.
Provides a table of emissivity values for various common substances.