SPARKcup- USER’S GUIDE - EUG
ROXELL - 025 - 0717
3
OPERATOR’S GUIDE
0717
02500569
1. BEFORE THE CHICKS ARRIVE
1. Take care to have a correct water pressure in the supply line : between 2,5
and 3 BAR Max. Use a central pressure restrictor.
The lines should meet the following requirements :
* Supply line up to the control panel : minimum 1” dia.
* Line between control panel and branch point of pressure regulators : between
1” and 1
1
/
2
”dia. (according to specifications in the identikit).
* Branch lines in the house up to the pressure regulator : opaque water hose
of min.
3
/
4
”dia.
2. Flush all the drinking lines. Make sure that you flush the lines long enough, i.e. at least
1minuteper10meterof drinking line.
3. Check the filter. Replace the filter cartridge if there is any difference between the water pressure before
and after the filter.
4. Install the conical float balls
5. Lower the lines. All cups must sink into the litter. Make sure that the cups are hanging vertically. Adjust
the suspension if necessary.
6. Adjust the pressure on the drinking lines between 0.15 and 0.25 BAR.
Replace the filter cartridge.
3Bar
IMPORTANT :
The HIGHER the water pressure, the LOWER the water level !
The LOWER the water pressure, the HIGHER the water level !
Pressures m entioned are indicative. The farmer's eye is the decisive factor !
Main point is that the user of a Sparkcup drinking system must judge the water level in the cups and adjust
the water pressure to get the desired water level.
ALWAYS CHECK DAILY WATER CONSUMPTION.
FLUSH DRINKING LINES EVERY WEEK (1MIN/ 10 M LINE).
FLUSH THE LINES PROPERLY AFTER ADMINISTRATING MEDICINES, VACCINES OR
CLEANING PRODUCTS.
GRADUALLY INCREASE HEIGHT OF DRINKING LINES AS ANIMALS GROW.